1.1 This test method covers the determination of hardness in water by titration with potentiometric detection via optical sensor. This test method is applicable to waters that are free of chemicals that will complex calcium or magnesium. The lower detection limit of this test method is approximately 2 mg/L to 5 mg/L as CaCO3; the upper limit can be extended to all concentrations by sample dilution. It is possible to differentiate between hardness due to calcium ions and that due to magnesium ions by this test method. 1.2 This test method is applicable to both colorless and colored water samples including groundwater, surface water, wastewater, and drinking water. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Product Details
Published: 04/15/2023 Number of Pages: 4 File Size: 1 file , 280 KB Note: This product is unavailable in Russia, Ukraine, Belarus